audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Duct > < Air Flow Flap Motor -V71-|Page 4143
Page 1
background image

Air Door Actuator / Motor: Service and Repair
Recirculation Flap Motor -V113-

Recirculation Flap Motor -V113-, Removing and Installing

NOTE:

-

Mark connecting element motor/flap when removing (danger of swapping with connecting elements of the other actuator motors).

-

For the malfunction "adaptation limit exceeded", check connecting element at motor, there must be no play between the shaft of the actuator motor
and the connecting element.

-

If the actuator motor makes clicking or rattling noises in regular intervals (approx. every 7 minutes), observe notes on (actuator motors for center
vent, removing and installing).

-

Remove plenum cover.

-

Remove windshield wipers and cowl panel complete

-

Remove cover with air flow flap.

-

Remove 4 screws -A-, pry off clips -B- and remove cover together with recirculating air flap from the air conditioner assembly.

-

Remove cover.

-

Remove 2 screws -A- and remove flap motor.

-

Before installing flap motor, check mounting of the air flow flap (knob -C- must be positioned between the stops -D-).

-

If the shaft of the motor is positioned in such a way that it is not possible to install the motor, see instructions regarding installation.

-

Tighten securing screws -A- only by hand, tightening torque 8 Ncm (0.7 in. lb).

-

After installing the cover, check that the grommet -B- is correctly located.

-

After installing, always check DTC memory.

Air Duct > < Air Flow Flap Motor -V71-|Page 4143