audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

A/C Signal|Testing and Inspection|Page 4491 > < A/C Signal|Testing and Inspection
Page 2
background image

-

In field -1- select "08 - Read Measuring Value Block".

Display on VAS 5051:

1

-

Enter display group, max. entered value = 255

-

Enter "050" in field -2- to select "display group number 050" and press -Q- button to confirm input.

Display on VAS 5051:

-

Switch A/C system off.
-

Specified value in display field 4: Compr. OFF

-

Switch A/C system on using "Auto" button and adjust A/C system to maximum cooling or heating power. Compressor must run.
-

Specified value in display field 4: Compr. ON

-

Depress gas pedal completely (swiftly) in first gear during a road test and then release it (brief acceleration).

Display on VAS 5051:

A/C Signal|Testing and Inspection|Page 4491 > < A/C Signal|Testing and Inspection