audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Generic Scan Tool|Page 5053 > < With Generic Scan Tool|Page 5051
Page 3
background image

 

-

Exit function "08 - Read Measuring Value Block" by pressing <- button.

If display field 3 shows an implausible value:

-

Disconnect Engine Coolant Temperature (ECT) sensor connector at -G2-/-G62- (arrow).

-

Connect multimeter between terminals -C- and -D- of sensor to measure internal resistance.

Range A shows resistance values for temperature range from 0 to 50 degree C, and range B shows values for temperature range from 50-100 degree C.

Read-out examples:

-

30 degree C corresponds to a resistance of 1500 to 2000 Ohm

-

80 degree C corresponds to a resistance of 275 to 375 Ohm

If specified value is not obtained:

-

Replace coolant temperature sensor.

If specified value is obtained:

-

Connect VAG1598/31 test box at wiring harness to ECM, do not connect ECM. See: Testing and Inspection/Reading and Clearing Diagnostic
Trouble Codes/Scan Tool Connecting/With Manufacturer's Scan Tool/Electrical Testing Using VAG1598/31 Test Box

-

Check following wire connections for open circuit and short circuit to Ground (GND) and B+:

Harness connector

VAG1598/31 test box

With Generic Scan Tool|Page 5053 > < With Generic Scan Tool|Page 5051