Connect one terminal of fuel injector to engine Ground (GND) using an adapter cable and an alligator clip from VAG1594A connector test kit.

-

Connect second terminal of fuel injector to B+ using VAG1348/3A remote control, VAG1348/3-2 adapter cable and assisting cable.

-

Bridge terminals 1 and 65 at test box using adapter cables from VAG1594A connector test kit (this step supplies Ground (GND) to one side of
relay coil for Fuel Pump (FP) relay).

-

Switch ignition on.
-

Fuel Pump (FP) must run.

-

Activate VAG1348/3A remote control for 30 seconds.

-

Perform measurement on all fuel injectors.

-

After all four fuel injectors have been activated, place measuring glasses on an even surface.
-

Specified value for each fuel injector: 179 ± 14 ml

-

If measured value of one or more fuel injectors is outside of specified range, switch Fuel Pump (FP) off (switch ignition off) and replace faulty
fuel injector.

-

If measured value of all fuel injectors is outside of the specified range, check fuel pressure. See: Fuel Pressure Regulator/Testing and Inspection

NOTE:  Also check spray pattern when checking injection quantity. Spray pattern must be the same for all injectors

-

Re-install fuel injectors together with fuel rail.