audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Manufacturer's Scan Tool|Page 3932 > < With Manufacturer's Scan Tool
Page 2
background image

-

Fuel Pump (FP) relay (at position 4 of micro-central electronics in driver's footwell, left) must trigger and Fuel Pump (FP) must run.

-

Exit function "03 - Output check diagnosis" by pressing <- button.

A If relay does not trigger:

-

Check voltage supply for Fuel Pump (FP).

-

Check activation of Fuel Pump (FP) relay.

B If relay triggers, but Fuel Pump (FP) does not run:

-

Check voltage supply for Fuel Pump (FP) and components (via Fuel Pump -FP- relay).

Checking voltage supply for Fuel Pump (FP)

-

Remove fuel pump relay.

-

Connect multimeter to terminal 17 of relay socket and Ground (GND) for voltage measurement.
-

Specification: approx. battery voltage

If specified value is not obtained:

-

Replace the micro-central electronics.

Checking activation of Fuel Pump (FP) relay

-

Turn off ignition.

-

Connect VAG1598/31 test box at wiring harness to ECM, do not connect ECM. See: Computers and Control Systems/Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Manufacturer's Scan Tool/Electrical Testing Using
VAG1598/31 Test Box

-

Connect socket 65 and socket 1 of test box to each other using adapter cable from VAG1594A connector test kit.

-

Switch ignition on.

With Manufacturer's Scan Tool|Page 3932 > < With Manufacturer's Scan Tool