If wire connection is OK:

-

Check Fuel Pump (FP) relay.

Checking output wire

-

Connect VAG1527B voltage tester as follows:

Electrical harness connector

Measure to

terminal
2

B+

-

Initiate output Diagnostic Test Mode. 

-

Press -> button until the following is indicated.

Indicated on display (LED must blink).

Output Diagnostic Test Mode

->

Leak detection pump Tank vent syst.

If LED does not blink:

-

Switch ignition off.

-

Remove windshield wiper arms (unscrew).

-

Disconnect cover for plenum chamber and place it on windshield side.

-

Disengage locking lugs and remove control module connector.

-

Connect VAG1598/31 test box to connector of wiring harness. Ground (GND) clip (arrow) at test box must be clipped to the battery negative
terminal. Engine Control Module (ECM) must not be attached.