Battery: Service and Repair
Battery Handling Instructions

Battery Handling Instructions

NOTE:

-

Battery terminals must no longer be greased.

-

To avoid damaging the battery housing, do not use force when attaching the battery clamps; press them on by hand.

-

The tightening torque for the battery clamps -arrow 1- is 6 Nm.

-

The tightening torque for the additional terminals on the battery clamps -arrow 2- is 6 Nm.

-

After reconnecting the battery, re-activate the vehicle's electrical equipment (radio, clock and convenience functions etc.) as explained in the
Owner's Manual and check that it is working.