Front Door Window Motor: Testing and Inspection
Basic Setting For Window Regulator Motor, Clearing

Basic Setting For Window Regulator Motor, Clearing

NOTES:

-

This procedure may be necessary if basic setting is interpreted as being insufficient, (for example, following a seal replacement.).

-

This means, that the window may unintentionally reverse itself during closing.

CAUTION:  The following procedures must be completed 3 times within one minute's time.

-

Close door and turn ignition on.

-

Open door window, and place a piece of wood (approx. 8-10 cm. high) between door window and upper door molding.

-

Close door window by pulling window regulator switch up.

-

Door window will stop upon contacting the wood, the pinch protection will activate and the window will reverse direction.

-

Close door window a second time by pulling window regulator switch up.

-

Door window will again stop upon contacting the wood, the pinch protection will again be activated, and the window will reverse direction.

-

Close door window a third time by pulling window regulator switch up.

-

The automatic reversing feature is now deactivated, and door window will remain in contact with the wood.

-

Door window will lower approx. 5 seconds after releasing door window regulator switch.

-

Close door window a fourth time by pulling window regulator switch up.

-

Door window will again stop upon contacting wood, but will not go down once window regulator switch is released.

-

Open door window by pressing window regulator switch.

-

Release window regulator switch.

-

Press window regulator switch down for at least 1 second.

-

Remove wood and close door window to top position (fully closed).

-

Release door window regulator switch.

-

Immediately pull window regulator switch up again for at least 1 second.

CAUTION:  The previous procedures must be repeated two more times.

-

Activate basic setting for window regulator motor