audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Electronic Power Control (EPC) Warning Lamp -K132-, Testing|Page 1596 > < Electronic Power Control (EPC) Warning Lamp -K132-, Testing|Page 1594
Page 2
background image

Warning lamp must go out after a few seconds.

If the warning lamp does not go out:

-

Switch off ignition.

-

Remove instrument cluster

-

Connect test box to control module wiring harness,  See: Powertrain Management/Computers and Control Systems/Testing and
Inspection/Component Tests and General Diagnostics/Test Box, Connecting For Wiring Test connect test box for wiring test.

-

Check wire connection between test box socket 48 and instrument cluster for short circuit to Ground (GND) according to wiring diagram

-

Erase DTC memory of ECM.  See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing and
Procedures/Diagnostic Mode 04 - Erase DTC Memory

-

Generate readiness code.  See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles
and Readiness Codes/Generate Readiness Code

If no malfunctions are detected in wire from Engine Control Module (ECM) to warning lamp:

-

Replace Motronic Engine Control Module (ECM) -J220-.

Electronic Power Control (EPC) Warning Lamp -K132-, Testing|Page 1596 > < Electronic Power Control (EPC) Warning Lamp -K132-, Testing|Page 1594