If the specification is obtained:

-

Connect test box to control module wiring harness, do not connect Engine Control Module (ECM),  See: Computers and Control Systems/Testing
and Inspection/Component Tests and General Diagnostics/Test Box, Connecting For Wiring Test connecting test box for wiring test.

Engine Codes AMU, ATC

-

Check wire between test box socket 64+2-pin connector terminal 2 for open circuit according to wiring diagram.

Wiring resistance: max. 1.5 Ohms

Engine Codes AWP, BEA

-

Check wire between test box socket 64+2-pin connector terminal 2 for open circuit according to wiring diagram.

Wiring resistance: max. 1.5 Ohms

All Vehicles

-

Also check the wire for short circuit to B+ and Ground (GND).
Specification: Infinite Ohms

-

Check wire between 2-pin connector terminal 1 and the Fuel Pump (FP) Relay -J17- for open circuit according to wiring diagram.

Wiring resistance: max. 1.5 Ohms

If no fault is detected in the wiring:

-

Replace Motronic Engine Control Module (ECM) -J220-