audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

EVAP Canister Purge Solenoid Valve 1, Checking|Page 3294 > < EVAP Canister Purge Solenoid Valve 1, Checking|Page 3292
Page 3
background image

Wiring resistance: max. 1.5 Ohms

-

Also check the wire for short circuit to B+ and Ground (GND).

Specification: Infinite Ohms

-

Check wire between 2-pin connector terminal 1 and the Fuel Pump (FP) Relay -J17- for open circuit according to wiring diagram.

Wiring resistance: max. 1.5 Ohms

If no fault is detected in the wiring:

-

Replace Motronic Engine Control Module (ECM) -J220-.