audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Evaporator Drain Tube|Testing and Inspection|Page 6734 > < Evaporator Drain Tube|Testing and Inspection|Page 6732
Page 1
background image

Evaporator Drain Tube: Service and Repair

Plenum Chamber Water Drain

Preparation

-

Remove wiper arms.

-

Remove rubber seal - 1 - and remove plenum chamber cover - 2 - by carefully pulling it off retainers on windshield.

Checking

‹› The draining of water from plenum chamber may be impaired by deposits (leaves, diverse tree needles etc.) accumulating in plenum chamber

water drains -  A -. The water level in the plenum chamber then rises if the vehicle is taken to an automatic car wash or in the event of heavy rain,
water enters via intake housing into the A/C unit and is blown by the Fresh Air Blower (V2) onto the evaporator together with the air conveyed. 

‹› If both water grommets - B - in water drains -  A - (right and left in plenum chamber) are blocked by leaves and pine needles, it may cause the

drains to freeze up in winter and water can no longer drain out. After a short drive, heat emitted from engine and exhaust system melts the ice in
the drains again and water may drain off again before vehicle arrives at the workshop.

Evaporator Drain Tube|Testing and Inspection|Page 6734 > < Evaporator Drain Tube|Testing and Inspection|Page 6732