audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 3022 > < Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 3020
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130), checking

Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130), checking

‹› Vehicle must be raised before the electrical connector for the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) is

accessible.

‹› Use only gold-plated terminals when servicing terminals in the electrical harness connector of the Oxygen Sensor (O2S) Behind Three Way

Catalytic Converter (TWC) (G130).

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› Fuse (SB6) OK.

‹› Motronic Engine Control Module (ECM) Power Supply Relay (J271) OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, shift selector lever into position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ replacing ] See: Engine Control Module/Testing and
Inspection/Engine Control Module (ECM) (J623).

Start diagnosis

-

Perform the function test in Diagnostic Mode 06. Refer to => [ Diagnostic Mode 06 - Read Test Results for Specific Diagnostic Functions ] See:
Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Modes 01 - 09/Diagnostic Mode 06 - Read Test Results for Specific
Diagnostic Functions.

If specified values are obtained:

-

End diagnosis and switch the ignition off.

If the specified values are not obtained:

-

Remove the retaining nuts - 1 and 2 - and cover. 

Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 3022 > < Heated Oxygen Sensor (HO2S) (G39) and Oxygen Sensor Regulation Before Catalytic Converter, Checking|Page 3020