Both shear bolts that are screwed into the ECM do not require heating to be removed. They can be removed without heat.
-
Disconnect metal retainers from connectors.
-
Remove both retainer bolts from ECM.
-
Disengage connector from ECM and remove connector.
-
Remove used ECM and connect new one.
Installing
Install in reverse order of removal.
-
After that, the ECM must be equipped with the metal retainer.
-
Clean threaded holes for shear bolts of locking compound residue. Cleaning can be performed with a thread cutter (tap).
-
Always use new shear bolts.
After installing new Engine Control Module, the following work steps must be performed:
-
Activate the engine control module in the "Guided Functions " operating mode under "Replace engine control module" on the vehicle diagnosis
and service system (VAS 5052).