Range A displays resistance values for the temperature range of 0...50 degree C, range B displays resistance values for the temperature range of 50...100
degree C
.

Read-out examples:

-

30 degree C corresponds to a resistance of 1500 to 2000 Ohm

-

80 degree C corresponds to a resistance of 275 to 375 Ohm

If specified value is not obtained:

-

Replace Engine Coolant Temperature (ECT) Sensor -G62- with Engine Coolant Temperature (ECT) Sensor -G2-.

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. See: Testing and Inspection/Scan Tool
Testing and Procedures/Scan Tool Testing/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase Diagnostic Data

-

Generate readiness code. See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes/Audi Drive Cycle/Readiness Code/With
Generic Scan Tool/Readiness Code, Generating

If no malfunctions are detected in the wires and the resistance values are OK:

-

Replace Motronic Engine Control Module (ECM) -J220-.