audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

With Manufacturer's Scan Tool|Page 3846 > < With Manufacturer's Scan Tool
Page 2
background image

Display on VAS 5051:

A -

1st control element in test

1

-

Evaporative emission (EVAP) canister purge regulator valve -N80-

-

The valve should click...

-

...and open and close (can be checked by blowing into auxiliary hose).

If valve does not click:

-

Test internal resistance of EVAP valve.

If the valve does not open and close properly:

-

Replace Evaporative emission (EVAP) canister purge regulator valve-N80-.

Testing internal resistance

-

Unplug connector on EVAP valve.

-

Connect multimeter between contacts 1 and 2 of valve (resistance measurement range).
-

Specification: 22 to 30 Ohms

If the specification is not attained:

-

Replace Evaporative emission (EVAP) canister purge regulator valve -N80-.

If the specification is obtained:

-

Test voltage supply.

Testing voltage supply

Requirements for test:

-

Fuse for EVAP valve OK.

-

Fuel pump relay OK. Testing. See: Computers and Control Systems/Testing and Inspection/Component Tests and General Diagnostics/Fuel Pump
(FP) Relay -J17-, Checking and Activating/With Manufacturer's Scan Tool

NOTE:  The EVAP valve receives its voltage supply via the fuel pump relay.

-

Unplug connector on EVAP valve.