audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Recirculation Valve For Turbocharger - N249, Testing|Page 4549 > < Air Recirculation Valve For Turbocharger - N249, Testing|Page 4547
Page 2
background image

^

Switch ignition on.

^

Specification: approximately 5 Volts

If the specification is not attained:

^

Connect test box V.A.G 1598/31 to wiring harness for engine control unit and also to the engine control unit itself (-1 -).

^

Test for open circuit and short to positive or Ground in the wiring connections:

^

Repair short circuit or open circuit if necessary.

If the specification is attained:

Testing signal wire 
^

Plug in connector on charge pressure sender.

^

Connect multimeter (voltage measurement range) between sockets 101 and 108 on test box.

^

Start engine and run at idling speed.

^

Specification: approximately 1.90 Volts

^

Increase engine speed by operating throttle quickly.

^

Specification: 2.00 - 3.00 Volts

If the specifications are not obtained:

Air Recirculation Valve For Turbocharger - N249, Testing|Page 4549 > < Air Recirculation Valve For Turbocharger - N249, Testing|Page 4547