Pull battery -4- free from retainer strip on battery mounting -1- and lift out of engine compartment.

Installing

NOTE:  The latest generation of batteries is equipped with a central gas venting system and a fine- mesh flame trap.

-

FUNCTION: The gases produced during charging escape through a central opening in the top of the battery. The flame trap, which prevents the
flammable gases in the battery from igniting, is also located at this point.

-

The flame trap is a small round fiberglass mat, about 15 mm in diameter and 2 mm thick. It operates like a valve and provides a vent for the gases
produced inside the battery.

There are two types of battery with central gas venting:

-

Batteries WITH vent hose and hose connection for central gas venting

-

Batteries WITHOUT vent hose and hose connection for central gas venting

NOTE:

-

If the battery has a hose and hose connection for the central gas venting system, it is important to make sure that the hose does not become pinched
when the battery is installed. If the hose is pinched, the gases will not be able to vent properly via the flame trap.

-

Even with batteries that do not have a vent hose, always check that the opening in the top of the battery -arrow- is not blocked.

-

Battery terminals must no longer be greased.

-

To avoid damaging the battery housing, do not use force when attaching the battery clamps; press them on by hand.

-

The tightening torque for the battery clamps -arrow 1- is 6 Nm.

-

The tightening torque for the additional terminals on the battery clamps -arrow 2- is 6 Nm.

-

Installation is performed in the reverse sequence.