audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Injection Vacuum Control Solenoid Valve|Locations|Page 5084 > < Air Injection Vacuum Control Solenoid Valve|Locations|Page 5082
Page 3
background image

-

Check wire connection from terminal 1 of connector via fuse S243 (in fuse holder, socket 43) to Fuel Pump (FP) relay for open circuit:

-

Check Fuel Pump (FP) relay. See: Computers and Control Systems/Testing and Inspection/Component Tests and General Diagnostics/Fuel Pump
(Fp) Relay -J17-, Testing and Activating

Checking activation

-

Connect VAG1527B voltage tester as follows:

Harness connector

Measure to

Terminal

2

B+

-

Initiate output Diagnostic Test Mode (DTM) and activate Secondary Air Injection (AIR) solenoid valve -N112-. See: Computers and Control
Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Manufacturer's Scan Tool

Indicated on display

Output Diagnostic Test Mode

->

Secondary air injection solenoid valve -N112

-

LED must blink.

If LED does not blink or if it remains constantly lit:

-

Connect VAG1598/31 test box at wiring harness to ECM, do not connect ECM. See: Computers and Control Systems/Testing and Inspection/Scan
Tool Testing and Procedures/Scan Tool Testing/Scan Tool Connecting and Initial Checks/Wiring and Component Testing Using VAG1598/31
Test Box

Air Injection Vacuum Control Solenoid Valve|Locations|Page 5084 > < Air Injection Vacuum Control Solenoid Valve|Locations|Page 5082