Indicated on display

Output Diagnostic Test Mode

->

EVAP canister purge regulator valve -N80

Valve must click...
...and must open and close (can be tested by blowing into assisting hose).

If valve does not click:

-

Check internal resistance of EVAP valve.

If valve does not open and close properly:

-

Replace Evaporative Emission (EVAP) canister purge regulator valve -N80-.

Checking internal resistance

-

Disconnect connector at EVAP valve.

-

Connect multimeter at valve for resistance measurement.
-

Specification: 22 to 30 ohms

If specified value is not obtained:

-

Replace Evaporative Emission (EVAP) canister purge regulator valve -N80-.

If specified value is obtained:

-

Check voltage supply.

Checking voltage supply

NOTE:  Voltage is supplied to the EVAP valve via the Fuel Pump (FP) relay.

Test requirement:

-

Fuse for the EVAP valve OK.

-

Disconnect connector at EVAP valve.

Emissions - EVAP Leak Detection Pump Quick Check|Page 5149 > < Emissions - EVAP Leak Detection Pump Quick Check|Page 5147