Connect VAG1527B voltage tester as follows:

Harness connector

Measure to

Terminal

1

Engine Ground (GND)

-

Operate starter briefly.
-

LED must light up.

If LED does not light up:

-

Check wire connection from terminal 1 to Fuel Pump (FP) relay via fuse for open circuit.

-

Repair open circuit if necessary.

If wire connection is OK:

-

Check Fuel Pump (FP) relay. See: Computers and Control Systems/Testing and Inspection/Component Tests and General Diagnostics/Fuel Pump
(Fp) Relay -J17-, Testing and Activating

If LED lights up:

-

Check activation.

Checking activation

-

Connect VAG1527B voltage tester to connector terminals 1 (B+) and 2.

-

Initiate output DTM and activate Evaporative Emission (EVAP) canister purge regulator valve -N80-. See: Computers and Control
Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Manufacturer's Scan Tool 
-

LED must blink.

If LED does not blink or if it remains constantly lit:

-

Connect VAG1598/31 test box at wiring harness to ECM, do not connect ECM. See: Computers and Control Systems/Testing and Inspection/Scan
Tool Testing and Procedures/Scan Tool Testing/Scan Tool Connecting and Initial Checks/Wiring and Component Testing Using VAG1598/31
Test Box

-

Check the following wire connection for open circuit and short circuit to Ground (GND) and B+:

Harness connector

VAG1598/31 test box

Emissions - EVAP Leak Detection Pump Quick Check|Page 5150 > < Emissions - EVAP Leak Detection Pump Quick Check|Page 5148