audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Level Sensor|FWD|Page 1610 > < Fuel Level Sensor|FWD|Page 1608
Page 2
background image

8. 4-pin harness connector 
9. 11 Nm 

10. Cap nut - 10 Nm
11. Ground (GND) connection

^

Installed position/test requirements, Refer to Fig 1

^

Check for tight fit of connector at metal ring of filler tube.

^

Securely tighten screw eyelet of electrical wire using cap nut item 14.

^

After installing, check electrical connection of metal ring at fuel filler tube to a blank portion of chassis using multimeter:

^

Specified value: approximately 0 Ohms

12. Nut -10 Nm
13. Bracket

^

For fuel filler tube

14. Sealing cap

^

With seal

15. Tensioning ring

^

Large diameter

16. Tensioning ring

^

Small diameter

17. Rubber cup

^

With overflow hose

18. Vent line

^

White

^

From EVAP canister

^

To Evaporative Emission (EVAP) canister purge regulator valve -N80

19. Vent line

^

To EVAP canister

^

Only remove together with tank protection valve and gravity valve

20. Fuel tank
21. 26 Nm
22. Mounting straps
23. 26 Nm
24. Clamping washer

^

Removing: turn to left

^

Installing: tighten to 2 Nm

25. 26 Nm

Fig. 1 Installation position of Ground (GND) connection

^

Route Ground (GND) connection as shown in figure.

^

Ensure connector -2- of Ground (GND) connection fits securely at metal ring -1- of fuel filler tube.

^

Disconnect Ground (GND) connection at both retaining clips (arrow).

Note:  Depending on construction version, a cable binder may be implemented in place of a clip.

Fuel Level Sensor|FWD|Page 1610 > < Fuel Level Sensor|FWD|Page 1608