To install: insert sender for rotation rate -G202- into mounting bracket and align straight before tightening.

Note:
-

The sender for rotation rate is sensitive to shocks or impact.

-

Do not install a sender which has dropped to the ground otherwise proper operation is not ensured.

Removing and installing sensor for transverse acceleration -G200-

-

Use screwdriver to pry mount -1- off sensor for transverse acceleration -G200- -2- and remove sender.

-

To install: insert sensor for transverse acceleration -G200- -1- in holder.

-

Installation position: sloping side (arrow) of sensor for transverse acceleration -G200- must face mount -2-.

-

Slip mount over sensor for transverse acceleration -G200- until it engages with a click.