To install insert Transverse Acceleration Sensor G200 -1- in holder.

^

Installation position: sloping side - arrow - of Transverse Acceleration Sensor G200 must face mount -2-.

-

Slip mount over Transverse Acceleration Sensor G200 until it engages with a click

Note:
^

The lateral acceleration sender is not resistant to shocks or impact.

^

Do not install a sender which has dropped to the ground otherwise proper operation is not ensured.

Installing

 

The remaining installation steps are carried out in the reverse sequence - note the following points:

-

Initiate basic setting for Transverse Acceleration Sensor G200 and Rotation Rate Sensor G202.

-

Perform ESP road test. See: Description and Operation/General Information