audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Sanden Compressor|Page 6169 > < Sanden Compressor|Page 6167
Page 3
background image

Fig. 3 Ribbed belt pulley, removing

-

Attach commercially available two-arm puller -A- at shoulder -B- and remove pulley.

NOTE:
-

To avoid damaging pulley when removing, make sure the puller is properly fitted to shoulder -B-.

-

Clean contact surface before installing.

-

If necessary, carefully tap the pulley into place using a plastic hammer and a suitable drift (applied to the bearing inner race).

Fig. 4 Magnetic coil, installing

-

Fit lug -C- into recess on magnetic coil -A-.

-

Make sure wiring harness -B- is correctly positioned in relation to magnetic coil -A-.

Fig. 5 Checking and adjusting gap

Gap width = difference between distance "1" and distance "2" measured as follows:

-

Measure distance "1" between belt pulley and clutch plate using depth gauge -A- (at three different points).

-

Apply 12 V to magnetic coil:
-

B+ terminal to single-pin connector -D-

-

Ground (GND) to compressor housing

-

Measure distance "2" between belt pulley and clutch plate using depth gauge -A- (at three different points).

Sanden Compressor|Page 6169 > < Sanden Compressor|Page 6167