Evaporator Drain Tube: Testing and Inspection

Evaporator Housing Drain Valve, Checking, Removing And Installing

Checking

-

Ensure that flap on valve -A- is not damaged, obstructed and is able to close freely. The flap opening must face downwards.

Removing and installing

-

Fold back pre-punched flap -D- in insulation mat and remove valve.

NOTE:
-

Remove valve -A- downwards from floor. When installing, make sure it is correctly positioned in bulkhead -B-.

-

When installed, the valve must not touch flap -D- in insulation mat.

-

The valve must not be sprayed with rustproofing wax or undercoating material.

-

If customer complaints mention dampness in the passenger compartment, ensure duct -C- is correctly positioned in valve -A-.

-

Two installed versions of valve are possible: version -1- through m.y. 2000 and version -2- (with two lower openings) installed as a running
change from m.y. 2001.