Checking voltage

-

Start engine momentarily.

-

Using a Multimeter, check the Secondary Air Injection (AIR) Pump Motor V101 electrical harness connector terminals 1 to 2 for voltage.

-

Switch the ignition off.

Specified value: battery voltage.

If the specified value was not obtained:

-

Using a Multimeter, check the Secondary Air Injection (AIR) Pump Motor V101 electrical harness connector terminal 2 to Ground (GND).

Specified value: battery voltage.

If the specified value was not obtained:

-

Check the wiring connection from the Secondary Air Injection (AIR) Pump Relay J299 socket 2/87 to the Secondary Air Injection (AIR) Pump
Motor V101 electrical harness connector terminal 2 for an open circuit or a short circuit.

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If the specified value was obtained:

Checking Ground (GND)

-

Using a Multimeter, check the Secondary Air Injection (AIR) Pump Motor V101 electrical harness connector terminal 1 to Ground (GND)
connection 2 (on left front long member) for resistance.