audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

EVAP Canister Purge Valve 2, Checking|Page 3074 > < All Technical Service Bulletins for Catalytic Converter:|241036|Page 3068
Page 1
background image

Canister Purge Solenoid: Testing and Inspection
EVAP Canister Purge Valve 2, Checking

EVAP Canister Purge Valve 2, Checking

Special tools, testers and auxiliary items required

-

Multimeter.

-

Wiring diagram.

Test requirements

-

Fuse S234 OK.

-

Fuel Pump (FP) Relay J17 OK.

-

The ignition switched off.

NOTE:  Voltage for the Evaporative Emission (EVAP) Canister Purge Solenoid Valve 2 N115 is supplied by the Fuel Pump (FP) Relay J17.

Test procedure

-

Perform a preliminary check to verify the customers complaint.  See: Computers and Control Systems/Testing and Inspection/Scan Tool Testing
and Procedures/General Diagnosis

Start diagnosis

-

Disconnect the exhaust system at the double clamp - arrows -.

-

Remove the right rear bracket for the exhaust system.

-

Disengage the rear part of the exhaust system on brackets.

NOTE:  Exhaust system decoupling element must not be bent more than 10 degrees, otherwise it may be damaged.

-

Remove the rear heat shield and bracket for the exhaust system - arrows -.

-

Remove the rear nut - arrow - from cover for EVAP canister.

EVAP Canister Purge Valve 2, Checking|Page 3074 > < All Technical Service Bulletins for Catalytic Converter:|241036|Page 3068