High Pressure Sensor G65|Page 710 > < High Pressure Sensor G65|Page 708
Page 2
background image

react to variable A/C compressor loads dependant of refrigerant system pressure. This signal may or may not appear as a duty cycle on the read
measuring value block display.

High pressure sensor -G65-, checking signal

-

Connect oscilloscope test leads to -G65- signal wire electrical testing, step 4.

The oscilloscope shows this signal pattern under the following conditions:

-

Ignition switched on (-G65- connected to positive and GND).

-

Oscilloscope settings: 2 V/Div. = (2 volts per grid division, direct current) 5 ms/Div. (5 milliseconds per grid division).

-

Oscilloscope test lead (signal wire) connected to terminal 2 on -G65-.

-

Oscilloscope test lead (shielding) connected to GND.

NOTE:  Signal pattern illustrated corresponds to a refrigerant system pressure of approx. 5 bar (equivalent to a signal ratio of approx. 20%). This
is the pattern that occurs at an ambient temperature of 20 degrees C (68 degrees F) when the compressor is not running and the refrigerant circuit
is full.

-

Pulse width -A- varies according to refrigerant system pressure. When the pressure rises, the pulse width increases.

-

Interval -B- between signals is always 20 milliseconds.

-

The signal ratio is the ratio between pulse width -A- and signal interval -B-.

High Pressure Sensor G65|Page 710 > < High Pressure Sensor G65|Page 708