Battery: Description and Operation
Battery With Central Gas Venting

Battery With Central Gas Venting

Function

New generation batteries are equipped with a central gas venting system and integrated flame trap. Function: Gases produced during charging escape
through a central opening on the side of the upper cover. The integrated flame trap prevents flammable gases in the battery from igniting. The flame trap
is comprised of a small round fiberglass mat with a diameter of 15 mm and a thickness of 2 mm. Working as a one-way-valve, it allows gases produced
during charging to vent.

There are two different types of batteries with central gas venting:

-

Batteries WITH external vent connection and hose for central gas venting.

-

Batteries WITHOUT vent connection and hose for central gas venting.

WARNING:

-

Only install batteries of the latest type with central gas venting.

-

Where equipped, ensure vent hose and hose connection are always secured to the battery housing during servicing.

-

Vent hose must not be kinked or pinched.

-

Always use genuine battery cell caps.Plugs must be installed with an O-ring seal.

Absorbent Glass MAT Battery Without Visual Indicator|Page 4987 > < Absorbent Glass MAT Battery Without Visual Indicator|Page 4985