background image

-

If the electrolyte level is too low, top up with distilled water using battery filler bottle VAS 5045 until the "Max." marking is reached.

NOTE:

-

The neck of filler bottle VAS 5045 is designed to prevent overfilling of the battery cells, which would cause the electrolyte to overflow. When the
"Max." level is reached, the flow of distilled water into the battery cell is cut off.

-

Use distilled water only, this prevents electrolyte impurities, which result in increased self-discharge.

-

Screw sealing plugs into battery cells, Batteries with central gas venting.

Electrolyte level too high

NOTE:  If the electrolyte level is too high, the leaking electrolyte (sulfuric acid/water mixture) will cause damage outside the battery, i.e. to components
in engine compartment.

If the electrolyte level is too high (i.e. above the plastic indicator web  inside the battery or above the "Max." marking on the outside), the excess fluid
must be extracted. This is done using a commercially available hydrometer.

-

Extract electrolyte using the hydrometer until the remaining fluid is level with the plastic indicator web or the "Max." marking.

-

Screw sealing plugs into battery cells, Batteries with central gas venting.

Batteries with central gas venting

WARNING:

-

Only install batteries of the latest type with central gas venting.

-

Always use genuine battery plugs. The plugs must be installed with an O-ring seal.

There are two different types of batteries with central gas venting:

-

Batteries WITH hose and hose connection for central gas venting

-

Batteries WITHOUT hose and hose connection for central gas venting