If the specified values are not reached, replace battery.

NOTE:  The measured values for the specific gravity of the individual battery cells must not deviate by more than 0.03 cu.kg/dm, otherwise the
battery should be replaced.

CAUTION:

Risk due to leaking battery acid.
-

To ensure the various battery connection systems are free of leaks, the batteries original sealing plugs must be installed in the
battery openings. Only replace missing or damaged sealing plugs with the same type of original plugs.

-

The sealing plugs must be equipped with an O-ring.

-

If the specified values are reached, reinstall battery cell sealing plugs.

NOTE:  If the battery must be replaced, follow the disposal regulations.