Wiring Harness: Removal and Replacement
Primary Connector With Flat Terminal Connector Systems

Primary Connector With Flat Terminal Connector Systems

Procedure

NOTE:  If necessary, housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing contacts.

Flat connector system with one retaining tab:

-

Guide release tool (which fits terminal housing) into release channel on terminal housing.

-

Grasp contact at wire and push gently into terminal housing - arrow -.

NOTE:  By pushing contact in direction of terminal housing, contact retaining tab is lifted off the housing shoulder and can be released using
release tool.

-

At the same time, push release tool in direction of terminal housing and pull released contact out of terminal housing - arrow -.

-

Remove release tool after removing contact from housing.

Flat connector system with two retaining tabs:

-

Guide release tool (which fits terminal housing) into release channel on terminal housing.

-

Grasp contact at wire and push gently into terminal housing until it stops - arrow -.

NOTE:  By pushing contact in direction of terminal housing, contact retaining tabs are lifted off the housing shoulder and can be released using
release tool.