audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Evaporator Drain Tube|Testing and Inspection|Page 7135 > < All Technical Service Bulletins for Evaporator Core:|871003|Page 7131
Page 1
background image

Evaporator Drain Tube: Testing and Inspection

Condensation Water Drain Hose, Checking

‹› Only one condensation water drain hose is installed in this vehicle. 

‹› On vehicles with heating (without A/C system), a sealing plug is installed to seal the opening on the body center tunnel (no condensation water

hose is present).

‹› There is no valve and no door at the end of the condensation water hose - C -.

‹› For complaints of moisture in passenger compartment, check the following as well as condensation water drain:

-

Plenum chamber water drain. Refer to => [ Plenum Chamber Water Drain ] See: Service and Repair

-

Plenum chamber cover and cover for fresh air intake housing for correct installation and damage. Refer to=> [ Fresh Air Intake Cover ] See: Body
and Frame/Cowl/Cowl Moulding / Trim/Service and Repair/Fresh Air Intake Cover

-

dust and pollen filter for soiling and correct installation. Refer to => [ Dust and Pollen Filter ] See: Cabin Air Filter/Service and Repair

-

Forced air extraction vents in luggage compartment. Refer to=> [ Passenger Compartment Forced Air Extraction, Checking ] See: Cabin
Ventilation Duct/Service and Repair.

-

Activation and function of back pressure door. Refer to=> [ Air Flow Door Motor, Function ] See: Air Door/Description and Operation/Air Flow
Door Motor, Function and recirculating air door, refer to=> [ Recirculation Door Motor ] See: Air Door/Air Door Actuator / Motor/Service and
Repair and Vehicle Diagnosis, Testing and Information System VAS 5051 under "Guided Fault Finding"

‹› Also, if there is complaint about moisture in the passenger compartment that only occurs when the is A/C compressor switched on and under

certain environmental conditions, check the output temperature of air from the evaporator Vehicle Diagnosis, Testing and Information System
VAS 5051 under "Guided Fault Finding":

-

Guided Fault Finding, in "read measured values block", select the measured value for Evaporator Vent Temperature Sensor (G263).

-

Check output temperature of air at evaporator under conditions reported by customer or at the following setting on the Climatronic Control
Module (J255) A/C control head, "Auto" operating mode, A/C compressor switched on (control light in AC button lights up), "Cold" temperature
setting, middle fresh air blower speed at a voltage of approximately 7 V on Fresh Air Blower (V2), fresh air mode (indicator light "Recirculation
button " does not light up) and open instrument panel vents.

-

If the Evaporator Vent Temperature Sensor (G263 ) measured value is too low (at an ambient temperature higher than 0 °C, for a longer time
colder than 0 °C) or too high (even though the A/C is working properly, higher than, for example, 10 °C), correct the cause for the difference.
When doing this following the procedure for checking the cooling output. Refer to => [ Cooling Output, Checking ] See: Testing and
Inspection/Component Tests and General Diagnostics/Cooling Output, Checking. 

Condensation water hose, removing, checking

-

Remove left and right center console trim and front center console.

Evaporator Drain Tube|Testing and Inspection|Page 7135 > < All Technical Service Bulletins for Evaporator Core:|871003|Page 7131