audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Expansion Valve, Removing and Installing|Page 7145 > < Expansion Valve|Testing and Inspection|Page 7142
Page 1
background image

Expansion Valve: Service and Repair
Expansion Valve, Removing and Installing

Expansion Valve, Removing And Installing

NOTE:  In model year 2007, the hose piece in the refrigerant line on the high pressure side (thin line) - C - was discontinued as a running change. Only
bend a refrigerant line - C - carefully and only as far as absolutely necessary to remove the expansion valve. If necessary, loosen this refrigerant line from
bracket so it is not damaged.

Removing

-

Switch off ignition.

-

Discharge refrigerant circuit.

-

Disconnect refrigerant lines from expansion valve.

-

Remove bolts - A -.

-

Pull expansion valve - B - out of heat protection insulation - C -.

NOTE:  Seal all open lines and connections on evaporator with suitable caps (avoid dirt and moisture from entering the system).

Installing

Torque specification: Bolts - A - (expansion valve to bracket on evaporator) - 10 Nm

Installation is carried out in the reverse order, when doing this note the following:

-

Replace O-rings - D - and - E -.

-

Make sure that O-rings - D - and - E - are properly seated on connecting pipes to evaporator - F - and - G -.

Expansion Valve, Removing and Installing|Page 7145 > < Expansion Valve|Testing and Inspection|Page 7142