audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Measurement Procedure|Page 970 > < Measurement Procedure
Page 1
background image

Alignment: Service and Repair
Measurement Procedure

Measurement Procedure

Special tools, testers and auxiliary items required

‹› Alignment Computer (V.A.G 1813) or VW-/Audi-approved alignment unit 

‹› Brake Pedal Actuator (V.A.G 1869/2)

‹› Insert Tool 18 mm (T10179)

‹› Shock Absorber Set (T10001)

Work Procedure, Vehicle Alignment, Overview

‹› Vehicle must only be measured at empty weight =>  See: Testing and Inspection/Component Tests and General Diagnostics. 

Observe the following work sequence!

1

Check front axle camber and adjust if necessary. 

a

Front and all wheel drive, refer to => [ Front Axle Camber, Adjusting ] See: Front Axle Camber, Adjusting

2

Check rear axle camber and adjust if necessary. 

a

Front and all wheel drive, refer to => [ Rear Axle Camber, Adjusting ] See: Rear Axle Camber, Adjusting

3

Check rear axle toe and adjust if necessary. 

a

Front and all wheel drive, refer to => [ Rear Axle Toe, Adjusting ] See: Rear Axle Toe, Adjusting

4

Check front axle toe and adjust if necessary. 

a

Front and all wheel drive, refer to => [ Front Axle Toe, Adjusting ] See: Front Axle Toe, Adjusting.

5

If adjustments were made to the suspension during alignment on vehicles with ESP or ABS, calibrate the steering angle sensor (G85) and
reprogram the steering, refer to => [ Wheel Alignment ] See: Wheel Alignment.

6

On vehicles with level control sensor, headlamp range control basic setting must be performed after a vehicle alignment, refer to => [ Rear Level
Control System Sensors ].

Use Vehicle Diagnosis, Testing and Information System (VAS 5051B) for this. => Vehicle Diagnosis, Testing and Information System VAS 5051 in
"Guided Fault Finding" function.

-

Insert brake pedal depressor (V.A.G 1869/2 ).

Measurement Procedure|Page 970 > < Measurement Procedure