audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Knock Sensor|Locations|Page 3666 > < Knock Sensor|Locations|Page 3664
Page 2
background image

Checking internal resistance

-

Using a Multimeter, check the Knock Sensor (KS) 1 (G61) terminals 1 to 2 for an internal short. 

Specified value: infinite (Infinity).

If the specified value was not obtained:

-

Replace Knock Sensor (KS) 1 (G61).

If the specified value was obtained:

Checking wiring

If the manufacturers test box is being used. Perform the following step.

-

Install the test box. See: Computers and Control Systems/Engine Control Module/Testing and Inspection/Engine Control Module

If the manufacturers test box is not being used. Perform the following step.

Knock Sensor|Locations|Page 3666 > < Knock Sensor|Locations|Page 3664