Oxygen Sensor: Testing and Inspection
Oxygen Sensor After Catalytic Converter, Checking

Oxygen Sensor after Catalytic Converter, Checking

Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130), Checking

‹› Use only gold-plated terminals when servicing terminals in the electrical harness connectors of the Oxygen Sensor (O2S) Behind Three Way

Catalytic Converter (TWC) (G130).

Test requirements

‹› Fuse (SB2) OK.

‹› Engine Control Module (ECM) (J623) fuses OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, shift selector lever into position " P" or "N".

‹› A/C switched off.

‹› Ground (GND) connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to =>  See: Computers and Control Systems/Testing and Inspection/Scan
Tool Testing and Procedures/Diagnostic Mode 09 - Read Vehicle Information.

Start diagnosis

-

Perform the function test in Diagnostic Mode 06. Refer to => [ Diagnostic Mode 06 - Read Test Results for Specific Diagnostic Functions ] See:
Computers and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Mode 06 - Read Test Results for Specific
Diagnostic Functions.

If specified values are obtained:

-

End diagnosis and switch the ignition off.

If the specified values are not obtained:

-

Remove the retaining screws - 1 and 2 - and the cover. 