Checking primary voltage

-

Disconnect the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector -  1 -.

-

Switch the ignition on.

-

Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminals
3 to 4 for voltage.

Specified value: 0.400 to 0.500 Volts

-

Switch the ignition off.

If the specified value was obtained:

-

Replace the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) ( G130). 

If the specified value was not obtained:

Checking wiring

If the manufacturers test box is being used. Perform the following step.

-

Install the test box.  See: Powertrain Management/Computers and Control Systems/Engine Control Module/Testing and Inspection/Engine Control
Module

If the manufacturers test box is not being used. Perform the following step.