Specified value: Battery voltage.

If the specification was not obtained:

-

Check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminal 4 to the Fuel Pump (FP) 2 Relay (J49) socket 2/87 an open
circuit, a short circuit to each other, Battery (+), or Ground (GND).

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the faulty wiring connection.

If the specification was obtained:

Checking Ground (GND) activation

If the manufacturers test box is being used. Perform the following step.

-

Install the test box. See: Powertrain Management/Computers and Control Systems/Engine Control Module/Testing and Inspection/Engine Control
Module 

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Replacing ] See: Powertrain Management/Computers
and Control Systems/Engine Control Module/Testing and Inspection/Engine Control Module.

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) electrical harness connector to the Engine Control Module (ECM) (J623) electrical
harness connector T81 for resistance.

Heated Oxygen Sensor Before Catalytic Converter, Checking|Page 728 > < Heated Oxygen Sensor Before Catalytic Converter, Checking|Page 726