TT Quattro Roadster L4-1.8L Turbo (AMU) (2002)
Indicated on display:
Read Measuring Value Block
Q
Input display group number XXX
-
Press buttons -0-, -5- and -6- to select "display group number 056" and press -Q- button to confirm input.
Indicated on display
Basic Setting 56
->
1
2
3
4
-
Check pressure switch/power steering in display field 4.
Display Group 056
If indications do not resemble description:
Check switch
-
Disconnect harness connector at pressure switch/power steering -F88-, at power steering pump.
-
Connect multimeter at switch for resistance measurement.
-
Start engine.
-
Specification: Infinity ohms (no continuity)