TT Quattro Roadster L4-1.8L Turbo (AMU) (2002)
Select function XX
-
Press buttons -0- and -4- to select "Initiate basic setting" and press -Q- button to confirm input.
NOTE: During basic setting, the Evaporative Emission (EVAP) canister purge regulator valve -N80- is closed and the A/C compressor is switched off
Indicated on display:
System in Basic Setting
Q
Input display group number XXX
-
Press buttons -0-, -0- and -2- to select "display group number 002" and press -Q- button to confirm input.
Indicated on display:
System in Basic Setting 2
->
1
2
3
4
-
Check specified values for load detection.
Display Group 002
If specified value is obtained:
-
Press -> button.
Indicated on display (function selection):
Rapid data transfer
HELP
Select function XX
Evaluation display group 002