audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Battery With Charge Indicator (Magic Eye), Checking|Page 4994 > < Battery With Charge Indicator (Magic Eye), Checking|Page 4992
Page 1
background image

Battery: Component Tests and General Diagnostics
Specific Gravity, Checking

Specific Gravity, Checking

WARNING:

-

Observe Warning and safety measures for lead acid batteries.

-

Always wear suitable protective clothing.

NOTE:

-

Audi TT equipped with the 3.2L V6 engine are equipped with an Absorbed Glass Mat (AGM) battery located in the left rear luggage compartment
in the spare tire/wheel well.

-

Unlike conventional lead-acid batteries, AGM batteries are completely sealed and use a fiberglass mat construction which completely absorbs the
electrolyte. As a result, no excess electrolyte is present, and it is not possible to check the electrolyte level or otherwise service the electrolyte.

-

If it is determined that an AGM battery is malfunctioning, replacement is necessary.

-

The following procedures apply only to batteries with removable cell caps.

WARNING:  DO NOT attempt to open an AGM battery.

Special tools, testers and auxiliary items needed

-

Commercially available hydrometer

-

Cleaning cloths

NOTE:

-

In conjunction with the "voltage under load" test, the specific gravity test gives a good indication of the battery condition.

-

The temperature of the electrolyte in the battery must be at least 10 degrees C.

-

The specific gravity can be checked immediately after charging battery.

CAUTION:

-

Dispose of electrolyte (sulfuric acid/water mixture) properly. Waste electrolyte must only be disposed of in appropriate waste disposal
sites. Refer to local regulations pertaining to electrolyte disposal.

-

To ensure effective sealing of the various battery cover systems, it is important to use the correct type of battery cell caps. If caps are lost
or damaged, always install new caps of the same type as originally installed.

-

Each cell cap must be installed with an O-ring seal.

The specific gravity must be checked in all battery cells as follows:

CAUTION:

Before beginning repairs on the electrical system
-

Switch off all electrical consumers.

-

Switch off ignition and remove ignition key.

-

Remove all battery plugs (battery cell caps).

Battery With Charge Indicator (Magic Eye), Checking|Page 4994 > < Battery With Charge Indicator (Magic Eye), Checking|Page 4992