audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Battery, Testing With Midtronics Battery/Starting/Charging System Analyzer MCR340A|Page 5002 > < Battery, Testing With Midtronics Battery/Starting/Charging System Analyzer MCR340A|Page 5000
Page 1
background image

Battery: Component Tests and General Diagnostics
Battery No-Load Voltage - Vehicles With Energy Management Control Module, Checking

Battery No-Load Voltage - Vehicles With Energy Management Control Module, Checking

NOTE:

-

No-load voltage measurement for assessment of battery condition is only appropriate if it is not possible to test battery with any of the VAS 505X
class testers.

-

Measuring the no-load voltage, e.g. within the prescribed maintenance and service work on vehicles in storage, determines if the battery must be
recharged.

Special tools, testers and auxiliary items required

-

Multimeter VAG 1526C, Multimeter Fluke 83 or equivalent (VAG tester illustrated here for reference only).

To ensure correct measurements, follow prerequisites and procedure exactly as given:

Prerequisites

-

Battery remains installed in vehicle. DO NOT disconnect battery ground cable.

-

Open front hood or rear lid as appropriate for access to battery terminals.

-

Manually place rear lid lock in "Closed" position to prevent illumination of luggage compartment lamp

-

Manually close front hood switch where applicable to prevent activation of front hood alarm.

-

Lock vehicle with remote control.

-

Battery must not be discharged by electrical consumers within 2 hours prior to measurement.

-

Battery must not be charged within 12 hours prior to measurement.

-

Battery temperature must be at least -10 degrees C.

Procedure

-

Perform any model-specific preparations necessary to gain access to battery terminals or battery jump-start terminals.

After a holding time of at least 2 hours:

-

Use multimeter to measure voltage between battery terminals or between battery jump-start terminals as applicable.
-

Specified value: 12.5 Volts or above = Battery OK.

-

If no-load voltage is under 12.5 Volts, charge battery.

-

After charging for 5 minutes, perform load test.  See: Battery, Load Testing With Midtronics Diagnostic Conductance Charging Station INC-940

-

If battery no-load voltage is below 11.7 Volts, battery is severely discharged.

-

If no-load voltage is OK, reconnect battery.

-

Follow measures required after reconnecting battery.

Battery, Testing With Midtronics Battery/Starting/Charging System Analyzer MCR340A|Page 5002 > < Battery, Testing With Midtronics Battery/Starting/Charging System Analyzer MCR340A|Page 5000