TT Quattro Roadster V6-3.2L (BHE) (2005)
^
Clamp off return line with hose clamp 3094.
^
Remove noise insulation tray.
-
Clamp off intake line with hose clamp 3094.
-
Place drip tray underneath vehicle.
-
Disconnect pressure line from pump.
On vehicles equipped with pressure switch, first disconnect connector and remove switch.
-
Insert adapter - 1 -.
Use a seal.
1 -
V.A.G 1402/1
2 -
V.A.G 1402/6 Hose from adapter set