TT Roadster L4-1.8L Turbo (AWP) (2003)
-
Connect multimeter (voltage measurement range) as follows:
Connector
Measure against
Contact
2
Engine Ground
-
Operate the starter briefly. (The engine can be allowed to start.)
-
Specification: approx. battery voltage
If the specification is not attained:
-
Test for open circuit or short to Ground in wiring between fuel pump relay and contact 2 on connector via fuse.
-
Correct short circuit or open circuit if necessary.
-
Connect hand-held multimeter (voltage measurement range) between contacts 2 and 3 of connector.
-
Operate the starter briefly. (The engine can be allowed to start.)
-
Specification: approx. battery voltage
NOTE: Contact 3 on the connector is for the Ground connection from the engine control module.
If the specification is not attained:
-
Test the wiring.