audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Not Available For Manufacturer's Scan Tool|Page 5618 > < Not Available For Manufacturer's Scan Tool
Page 1
background image

Leak Detection Pump: Testing and Inspection
With Generic Scan Tool

Check Leak Detection Pump (LDP)

Recommended special tools and equipment

-

VAG1526 multimeter or VAG1715 multimeter

-

VAG1594 connector test kit

-

Wiring diagram

Test requirements

-

The respective fuses of Leak detection pump (LDP) -V144- must be OK:

-

Ignition switched off.

Test sequence

-

Remove right front wheel

-

Remove front right wheelhousing liner.

-

Disconnect connector of Leak detection pump (LDP) -V144- (arrow).

-

Connect multimeter for resistance measurement as follows.

Leak detection pump (LDP) -V144-

Specified value

Terminal

1 + 3

640 ... 720 Ohm

2 + 3

15 ... 17 Ohm

If specified values are not obtained:

-

Replace Leak detection pump (LDP) -V144-, item 4

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data. See: Computers and Control
Systems/Testing and Inspection/Scan Tool Testing and Procedures/Scan Tool Testing/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase
Diagnostic Data

-

Generate readiness code. See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes/Audi
Drive Cycle/Readiness Code/With Generic Scan Tool/Readiness Code, Generating

If specified values are obtained:

-

Connect VAG1598/31 test box to connectors of wiring harness. Ground (GND) clip (arrow) at test box must be clipped to battery minus. Do not
connect Engine Control Module (ECM).

Not Available For Manufacturer's Scan Tool|Page 5618 > < Not Available For Manufacturer's Scan Tool