audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Not Available For Manufacturer's Scan Tool|Page 4385 > < Not Available For Manufacturer's Scan Tool
Page 1
background image

Turbo Boost Sensor: Testing and Inspection
With Generic Scan Tool

Charge Air Pressure Sensor, Checking

Recommended special tools and equipment e.g.:

-

VAG1526 multimeter or VAG1715 multimeter

-

VAG1594 connector test kit

-

Wiring diagram

Checking voltage supply and wiring to control module

-

Switch ignition off.

-

Disconnect connector at charge air pressure sensor.

-

Use adapter cables from VAG1594 to connect multimeter to terminals 1 + 3 of connector for voltage measurement.

-

Switch ignition on.
Specified value: at least 4.5 V

-

Switch ignition off.

If specified value is not obtained:

-

Connect VAG1598/31 test box to control module wiring harness. Engine Control Module (ECM) is not connected.

-

Check for open circuits in wires between test box and connector according to wiring diagram.
Terminal 1 + socket 108