audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Detaching Refrigerant Pipes From Condenser/Re-Attaching|Page 6665 > < Detaching Refrigerant Pipes From Condenser/Re-Attaching|Page 6663
Page 4
background image

-

Remove bolts - arrows - by releasing air ducts at left and right and tipping in direction of headlamps.

-

Tip top edge of cooler back slightly.

-

Disengage cooler from lower mounting points by raising it.

-

Slide cooler in direction of engine.

-

Support cooler from below so that it cannot sink.

NOTE:  Do not bend or stretch lines or hoses as compressor and refrigerant lines/hoses may be damaged.

-

Remove bolts - arrows -.

-

Remove condenser from cooler.

-

Remove condenser downward.

Installing

-

Torque specification: Bolts for securing compressor (to charge air cooler) - 5 Nm

Installation is done is reverse order, observe the following:

NOTE:  The removed condenser contains refrigerant oil that must be returned to the refrigerant circuit (with the new condenser).

-

Ensure sealing strips - arrows - have adhered correctly to condenser - A -.