audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Removal and Replacement|Page 6765 > < Removal and Replacement|Page 6763
Page 3
background image

-

Hold a container - B - under the lower connection -  C -.

-

Using a compressed air gun - D -, carefully blow coolant out of heater core (into container - B -).

-

Disconnect refrigerant lines from the expansion valve. Refer to=> [ Refrigerant Lines, Disconnecting and Connecting from Expansion Valve ] See:
Service and Repair/Removal and Replacement/Refrigerant Circuit and secure (for example, with cable tie) so they do not interfere during
installation.

‹› Seal open pipe connections.

‹› To seal off all open connections on expansion valve or evaporator, sealing caps from a replacement expansion valve or a replacement evaporator

can be used (preventing dirt and moisture from entering the system).

-

Remove the glove compartment, the driver storage compartment, the front part of the center console and the instrument panel

‹› To prevent the instrument panel shell from damage, instrument panel should be placed on a clean work bench which is covered with clean

cardboard. 

-

Remove both left and right footwell vents.

-

Remove the Fresh Air Blower (V2), refer to => [ Fresh Air Blower Control Module and Fresh Air Blower ] See: Blower Motor/Description and
Operation

-

Remove the instrument panel crossmember (central tube).

-

Remove Data Bus On Board Diagnostic Interface ( J533) (secured to bracket - A - in area of steering column).

-

Remove the screws - B - and remove the bracket -  A - from the A/C unit (heater). The bracket remains attached to the wiring harness inside the
vehicle.

Removal and Replacement|Page 6765 > < Removal and Replacement|Page 6763